· 4 min read · Meta Smart Factory Team
NIS2 is now national law in most of Central Europe, and manufacturers are registering, naming the people responsible and writing their first security policies. Most of that work is IT work. Part of it lands on the shop floor, where the MES, SCADA and the links to the PLCs sit.
NIS2 is the EU directive on cybersecurity for essential and important entities, and over the past two years the member states have written it into their own laws. Manufacturing is one of the sectors it names. For a plant, the questions that matter come down to whether the company is in scope, what the law asks for, and which part of it touches production systems. This article covers the last part in the most detail, because that is where MES and machine connectivity come in.
The directive lists manufacturers of machinery and equipment, motor vehicles and other transport equipment, electrical equipment, computer, electronic and optical products and medical devices, and it also covers chemicals and food production and distribution. Size matters too: as a rule, the obligations apply to medium-sized and large companies in those sectors. Each country set its own details, so the national law and its registration rules are the place to check.
Czechia's new cybersecurity act, 264/2025, has applied since 1 November 2025. A company that meets the criteria registers with NÚKIB within 60 days and then has one year from the registration decision to put the measures in place, so many of those deadlines fall in the coming months.
In Poland, the amended act on the national cybersecurity system has applied since 3 April 2026. Companies that already met the criteria on that date had until 3 October 2026 to apply for entry in the register, and companies that meet them later have six months to apply. Austria's NISG 2026 took effect on 1 October 2026, and companies in scope must register through the USP business portal within three months; the Austrian Economic Chamber advises registering by 31 December 2026.
Slovakia's act 366/2024 has applied since 1 January 2025 and Romania's emergency ordinance 155/2024 since 31 December 2024. Slovenia's ZInfV-1 has applied since 19 June 2025, and Croatia's Cybersecurity Act since February 2024. Bulgaria's amended law took effect on 17 February 2026.
Outside the EU, Serbia's new Law on Information Security, aligned with NIS2, has applied since 31 October 2025. In Türkiye, manufacturing is on the list of critical infrastructure sectors set under Cybersecurity Law No. 7545 in May 2026. Saudi Arabia's National Cybersecurity Authority has published controls for operational technology, OTCC-1:2022.
Machine builders have one more date. Under the Cyber Resilience Act, manufacturers of products with digital elements have had to report actively exploited vulnerabilities and severe incidents since 11 September 2026.
The measures in Article 21 of the directive read like an IT list: risk analysis and security policies, incident handling, business continuity with backups and recovery, security in the supply chain, secure purchasing and maintenance of systems, training and basic cyber hygiene, encryption, personnel security, access control and asset management, multi-factor authentication where it fits, and a check that the measures actually work. On the shop floor most of them turn into concrete questions. Which controllers are connected, and to what? Who can reach the MES and the PLC network, and from where? What happens to production records if a server fails? What has the software supplier promised about its own security?
Reporting is the other part. A significant incident needs an early warning within 24 hours and a notification within 72 hours. A final report follows within one month of that notification. A plant that cannot tell quickly what is connected to what will struggle with the first deadline.
Does the data collector write to the controllers? In PLC data collection from Meta Smart Factory, collection is read-only by default: no write items are configured in the collector, the tag or data block list is agreed with whoever maintains the PLC programme, and PUT/GET or the brand's equivalent is restricted on the controller. Anything that writes back to a machine, such as a recipe download at changeover, is a separate connection, scoped on purpose.
Is the control network separated? The PLC sits on its own VLAN, and the collector talks to the rest of the system through a secure gateway proxy.
Which way do the connections go? The collector connects outbound over TLS or a site-to-site VPN, so no firewall port is opened towards the plant. Plants that already run SCADA or an OPC server can feed the MES from that server's tag tree, and then no new device talks to the controllers at all.
Who can see and change what? Access is role-based, and where data must not leave the building, the platform runs on-premise or as a dedicated single-tenant environment. AI vision inference always runs on a GPU server at the plant.
The information security management system of Meta Smart Factory d.o.o. is certified to ISO/IEC 27001:2022, and the certificate covers how the platform is designed, developed, deployed, operated, maintained and supported, including its cloud-hosted infrastructure. For a customer under NIS2 that is evidence for the supply-chain part of the risk assessment. The obligations themselves stay with the company in scope: its registration, its policies, its incident reporting and its decisions about which systems connect to which.
A practical first step for production is an inventory that IT and the plant agree on: every controller, every gateway, every server and every connection between them, with an owner for each. The rest of the measures build on that list, and the MES project is a good moment to write it down.
Discuss This With Our ExpertsIt applies to medium-sized and large manufacturers in the sectors the directive names, such as machinery, motor vehicles, electrical equipment, electronics, medical devices, chemicals and food. The exact scope and the registration rules come from each country's national law.
A read-only connection reduces risk, but NIS2 asks for a set of measures across the company, including risk analysis, access control, backups, supplier security and incident reporting. The way machines are connected is one part of that assessment.