← All Products
🖥️
Hardware

Smart Touch Panels & META Smart I/O

Industrial hardware that connects any machine, any age

MSF Smart Touch-Screen Industrial Panels give operators a rugged, intuitive interface at every workstation, while META Smart I/O devices connect machines of any generation to your digital factory.

Request a DemoStart a PoC

What do industrial touch panels and Smart I/O devices do on the shop floor?

Industrial touch panels are rugged operator terminals at each workstation, and Smart I/O devices read machine signals so that output and machine status reach the MES. Meta Smart Factory's IP65 capacitive panels let operators report production, downtime and scrap and call maintenance, quality or material with one touch, while META Smart I/O counts cycles and detects machine states on machines of any age, typically live within hours.

Key Features

Rugged industrial panelsCapacitive touch screens built for dust, oil and gloves, with an IP65 front and 24/7 duty.
Plug & play I/O deviceMETA Smart I/O reads signals, counts cycles and detects machine states on legacy machines.
PLC connectivityNative drivers for Siemens, Rockwell, Schneider, Beckhoff, Mitsubishi, Omron, Delta, Keyence and WAGO, plus OPC UA, Modbus TCP/RTU, EtherNet/IP and MQTT.
Andon & alertsPanels double as andon displays: call maintenance, quality or material with one touch.
Offline resilienceLocal buffering keeps data safe even if the network drops.
Fast installationA workstation is typically connected and live within hours.
Safety circuits are never tappedNothing is taken off a light curtain, e-stop chain, two-hand control or safety relay. Where the only per-part signal sits there, a separate sensor is fitted instead.
Read through isolation, not into the circuitSignals are read through an interposing relay or isolated input, so the machine's own circuit is neither loaded nor altered. A cabinet is still opened: get written agreement under warranty.
One pulse, agreed part definitionBefore counting starts, someone confirms what a pulse means: multi-cavity tools give several parts per stroke, and some machines pulse more than once per part.
Operator scrap entry closes the gapA device on a machine gives availability and output; quality data needs another source. Scrap is captured on the panel, from a quality check, a test rig signal or a camera.
Watch for machines that go silentA drifting sensor or a signal tap lost to a cabinet rewire shows up as silence, and nobody complains; a spare panel and I/O unit on site turn a failure into a swap.
Existing OPC UA server as a routePlants with SCADA or an OPC server feed the curated tag tree, so no new device talks to the controllers. This is often the fastest path where nobody wants one there.
Deep diveIndustrial IoT for Smart Factories: Connecting 20-Year-Old Machines Without Replacing ThemThe average factory is not new, and it does not need to be. How IIoT hardware retrofits legacy machines into a smart factory: smart I/O, energy meters, LoRaWAN, RFID and RTLS, installed in hours.Read the full article →

At a Glance

IP65Protection class
hrsInstall per station
anyMachine age
24/7Duty cycle

Technical Specifications

Native PLC drivers
Read by the MSF platform: Siemens S7comm/S7-Light, Rockwell AB-ETH/Logix/DF1, Schneider UMAS, Beckhoff ADS, Mitsubishi MC, Omron FINS, Delta DVP, Keyence KV, WAGO (vendor-native).
Open protocols
OPC UA, Modbus TCP and Modbus RTU, EtherNet/IP and MQTT.
Retrofit signals
Cycle or eject contact, stroke signal or a fitted proximity sensor for counting; a lamp, motor or drive-enable circuit for availability. Safety circuits excluded.
Electrical interface
Read through an interposing relay or isolated input; signal voltage established during the site survey, since 230 V lamp and 24 V PLC circuits differ.
Data buffering
Local recording during network or server loss, backfilled on reconnect, hold time set by event rate and buffer size; on power loss nothing is buffered and gaps are filled by hand.
Site requirements
Power at each panel, preferably a wired Ethernet drop per station, UPS for panels and I/O units, plus cable runs, mounting arms and cabinet space.
Workstation commissioning
Typically connected and live within hours.
Machine wiring
A short planned stop per machine at a changeover, by a qualified electrician with the machine isolated; cable runs and cabinet space are usually the schedule item.
Deep diveWhich PLCs Work with MSF? Native Drivers for Siemens, Allen-Bradley, Schneider, Beckhoff, Mitsubishi, Omron, Delta, Keyence and WAGOThe first question every controls engineer asks about an MES: "does it talk to OUR PLCs?" Here is the full answer: nine PLC families with native drivers, plus OPC UA, Modbus, EtherNet/IP and MQTT for everything else.Read the full article →

Frequently Asked Questions

Can it connect 30-year-old machines?

Yes. That's exactly what META Smart I/O is for: sensors and signal taps digitalize even fully mechanical machines.

Do panels run only MSF software?

They're optimized for MSF MES but can display other web applications too.

Can existing PLCs be connected without reprogramming?

Existing PLCs are read directly via native drivers or OPC-UA, with no reprogramming required.

What signal does Smart I/O need to count parts?

A per-part event it can see electrically: a cycle or eject contact, a stroke signal, or a proximity sensor fitted for the purpose. For availability a state signal is enough, such as a lamp, motor or drive-enable circuit, but a lamp cannot count parts. Someone has to confirm what one pulse means, because a multi-cavity tool gives several parts per stroke and some machines pulse several times per part.

Who wires a machine monitoring device into a machine?

A qualified electrician, with the machine isolated: this is work inside a control cabinet. Safety-related circuits are never tapped, so nothing is taken off a light curtain, e-stop chain, two-hand control or safety relay; if the only per-part signal sits on one of those, a separate sensor is fitted instead. Signal voltage has to be established during the survey, because a 230 V lamp circuit and a 24 V PLC signal need different input handling.

Does connecting a machine to Smart I/O affect its warranty?

It should not, because signals are read through an interposing relay or an isolated input, so the machine's own circuit is neither loaded nor altered. But a cabinet still gets opened, so on a machine under manufacturer warranty or a service contract, get written agreement first, before a breakdown starts the argument. Machine builders differ, and some treat any wiring in their cabinet as grounds to refuse a claim.

Can Smart I/O tell a good part from a scrap part?

No. It counts cycles and reads machine states; it does not know what came out. Scrap has to come from the operator on the panel, from a quality check, from a downstream test rig with its own signal, or from a camera. A device on a machine gives you availability and output but no quality data, so plan that gap deliberately or gross output ends up being reported as good output.

What happens to the data if the network or the server goes down?

It depends which one. If the network or server drops, the I/O device keeps recording locally and backfills when the link returns; hold time depends on event rate and buffer size, and timestamp accuracy depends on the device's clock between NTP syncs. If the machine loses power, nothing is buffered and the gap is filled by hand or not at all, which is why panels and I/O units worth trusting sit on a UPS. An operator on a dead panel records nothing.

What power and network does each workstation need?

Power at the panel and, preferably, a wired Ethernet drop for each one. Wi-Fi works, but a hall full of steel, welders and moving cranes is a poor place to depend on it, and a panel that drops its session mid-order loses operator trust quickly. Cable runs, mounting arms and cabinet space are usually the real schedule item. The hardware rarely is. Budget a short planned stop per machine and put it at a changeover.

What maintenance do these devices need once they are installed?

Little day to day, but they are not fit-and-forget. Panel glass needs cleaning, added sensors drift or get knocked out of alignment during machine maintenance, and a signal tap can go silent after somebody rewires a cabinet. The practical control is watching for machines that stopped reporting before anyone complains, and keeping a spare panel and I/O unit on site so a failure is a quick swap.

Ready to See Your Factory's Potential?

Get a free demo and a Proof of Concept plan tailored to your production.

Request a Demo